E-ISSN 2705-3954 | ISSN 0794-4756
 

Original Research 


HARMONICS MITIGATION USING DELTA CONNECTED CASCADED H-BRIDGE BASED ACTIVE POWER FILTER

Aminu Jibrin Aliyu, Adamu Saidu Abubakar, Abdullahi Bala Kunya, Sani Salisu.

Abstract
Nonlinear loads, such as power electronics introduces harmonics into the power system, and in-turn, the power quality of the system is affected. Shunt Active Power Filter (SAPF) among other techniques used in solving current harmonics related problems has proven to be the most prolific. In this research paper a cascaded H-bridge in delta connection is designed to introduce the compensating current into the power system. Level shifted Pulse Width Modulation Scheme was deployed for the generation of control pulses. The control strategy is simulated in MATLAB/Simulink environment, and its effectiveness was tested on balanced supply. The Fast Fourier Transform (FFT) analysis showed that the THD was reduced from 30.76% to 3.89%. The result shows the effectiveness of the developed SAPF and conformity with IEEE 519 standard.

Key words: active power filter; fast Fourier transform; reference current generation; CHB


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by Aminu Jibrin Aliyu
Articles by Adamu Saidu Abubakar
Articles by Abdullahi Bala Kunya
Articles by Sani Salisu
on Google
on Google Scholar

How to Cite this Article
Pubmed Style

Aliyu AJ, Abubakar AS, Kunya AB, Salisu S. HARMONICS MITIGATION USING DELTA CONNECTED CASCADED H-BRIDGE BASED ACTIVE POWER FILTER. NJE. 2021; 28(3): 70-74.


Web Style

Aliyu AJ, Abubakar AS, Kunya AB, Salisu S. HARMONICS MITIGATION USING DELTA CONNECTED CASCADED H-BRIDGE BASED ACTIVE POWER FILTER. https://www.njeabu.com.ng/?mno=136255 [Access: January 09, 2024].


AMA (American Medical Association) Style

Aliyu AJ, Abubakar AS, Kunya AB, Salisu S. HARMONICS MITIGATION USING DELTA CONNECTED CASCADED H-BRIDGE BASED ACTIVE POWER FILTER. NJE. 2021; 28(3): 70-74.



Vancouver/ICMJE Style

Aliyu AJ, Abubakar AS, Kunya AB, Salisu S. HARMONICS MITIGATION USING DELTA CONNECTED CASCADED H-BRIDGE BASED ACTIVE POWER FILTER. NJE. (2021), [cited January 09, 2024]; 28(3): 70-74.



Harvard Style

Aliyu, A. J., Abubakar, . A. S., Kunya, . A. B. & Salisu, . S. (2021) HARMONICS MITIGATION USING DELTA CONNECTED CASCADED H-BRIDGE BASED ACTIVE POWER FILTER. NJE, 28 (3), 70-74.



Turabian Style

Aliyu, Aminu Jibrin, Adamu Saidu Abubakar, Abdullahi Bala Kunya, and Sani Salisu. 2021. HARMONICS MITIGATION USING DELTA CONNECTED CASCADED H-BRIDGE BASED ACTIVE POWER FILTER. Nigerian Journal of Engineering, 28 (3), 70-74.



Chicago Style

Aliyu, Aminu Jibrin, Adamu Saidu Abubakar, Abdullahi Bala Kunya, and Sani Salisu. "HARMONICS MITIGATION USING DELTA CONNECTED CASCADED H-BRIDGE BASED ACTIVE POWER FILTER." Nigerian Journal of Engineering 28 (2021), 70-74.



MLA (The Modern Language Association) Style

Aliyu, Aminu Jibrin, Adamu Saidu Abubakar, Abdullahi Bala Kunya, and Sani Salisu. "HARMONICS MITIGATION USING DELTA CONNECTED CASCADED H-BRIDGE BASED ACTIVE POWER FILTER." Nigerian Journal of Engineering 28.3 (2021), 70-74. Print.



APA (American Psychological Association) Style

Aliyu, A. J., Abubakar, . A. S., Kunya, . A. B. & Salisu, . S. (2021) HARMONICS MITIGATION USING DELTA CONNECTED CASCADED H-BRIDGE BASED ACTIVE POWER FILTER. Nigerian Journal of Engineering, 28 (3), 70-74.