The saturation effect of permanent magnet magnetic property such as the flux density, on electromagnetic characteristics of a double stator (DS) permanent magnet (PM) machine is investigated in this study. The studied parameters are: flux linkage, induced voltage, torque characteristics and total harmonic distortion (THD). Maxwell-2D software is employed to predict the results using Finite Element Analysis (FEA) procedure.
The FEA-calculated flux linkage value of the studied machine at magnetic flux densities of 1 Tesla, 2 Tesla, 3 Tesla and 4 Tesla are 0.0085 Wb, 0.0106 Wb, 0.0086 Wb and 0.0067 Wb. The corresponding maximum static torque of the machine are 2.0427 Nm, 2.5596 Nm, 2.2377 Nm and 1.8306 Nm. Optimum value of magnetic flux density would yield large value of flux linkage and a corresponding large amount of torque, provided the machine is not saturated; in other words, the best machine performance is predicted under normal working conditions of rated speed, load and optimal magnetic flux density value. It is revealed that, for a given permanent magnet machine having neodymium-iron-boron magnet, its optimal electromagnetic performance is obtained when its magnetic flux density magnitude is about 2 Tesla; beyond this value of magnetic flux density, the machine’s performance tends to reduce, owing to the saturation effect of the implemented magnetic material.

Key words: Machine, magnetic property, saturation, torque ripple and voltage distortions.


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by Chukwuemeka Chijioke AWAH
on Google
on Google Scholar

How to Cite this Article
Pubmed Style

AWAH CC, . Saturation Effect of Magnetic Flux Density on the Performance of a Double Stator Machine. NJE. 2023; 30(3): 61-66.


Web Style

AWAH CC, . Saturation Effect of Magnetic Flux Density on the Performance of a Double Stator Machine. https://www.njeabu.com.ng/?mno=148387 [Access: January 04, 2024].


AMA (American Medical Association) Style

AWAH CC, . Saturation Effect of Magnetic Flux Density on the Performance of a Double Stator Machine. NJE. 2023; 30(3): 61-66.



Vancouver/ICMJE Style

AWAH CC, . Saturation Effect of Magnetic Flux Density on the Performance of a Double Stator Machine. NJE. (2023), [cited January 04, 2024]; 30(3): 61-66.



Harvard Style

AWAH, C. C. & (2023) Saturation Effect of Magnetic Flux Density on the Performance of a Double Stator Machine. NJE, 30 (3), 61-66.



Turabian Style

AWAH, Chukwuemeka Chijioke, and . 2023. Saturation Effect of Magnetic Flux Density on the Performance of a Double Stator Machine. Nigerian Journal of Engineering, 30 (3), 61-66.



Chicago Style

AWAH, Chukwuemeka Chijioke, and . "Saturation Effect of Magnetic Flux Density on the Performance of a Double Stator Machine." Nigerian Journal of Engineering 30 (2023), 61-66.



MLA (The Modern Language Association) Style

AWAH, Chukwuemeka Chijioke, and . "Saturation Effect of Magnetic Flux Density on the Performance of a Double Stator Machine." Nigerian Journal of Engineering 30.3 (2023), 61-66. Print.



APA (American Psychological Association) Style

AWAH, C. C. & (2023) Saturation Effect of Magnetic Flux Density on the Performance of a Double Stator Machine. Nigerian Journal of Engineering, 30 (3), 61-66.